Ferritin Quantitative Test

Dengue Ag&Ab Combo Rapid Test

The Dengue Ag&Ab Combo Rapid Test is a rapid membrane based chromatographic immunoassay for for the qualitative detection of NS1 antigen and IgM/IgG antibodies to all four serotypes (DEN-1, DEN-2, DEN-3 and DEN-4) of Dengue virus in human serum, plasma or whole blood. It is intended to be used by professionals as a screening test and provides a preliminary test result to aid in the diagnosis of primary and secondary Dengue infection.


For professional in vitro diagnostic use only.




Product Detail

Features


  • Highly Sensitive & Specific
  • Flexible Samply Type
  • Fast in 15 minutes
  • Simple Operation

Included Materials


  • Test Cassette 
  • Sample Buffer
  • Droppers
  • Instruction for Use


Test Procedure 


The test should be operated at room temperature 59-86°F(15-30℃).
1. Allow the test cassette, specimen and buffer to reach room temperature (15-30°C) before testing.
2. Remove the test cassette from the foil pouch and use it as soon as possible.

3. Place the test cassette on a flat and clean surface. Transfer the specimen by a pipette or a dropper:

To use a Pipette:

4. Transfer 10 μL of Serum, Plasma, or Whole blood specimen into the Sample Well (S) of the test cassette, then add 2 drops of buffer into the Buffer Well (B) and start the timer. Avoid air bubbles in the Sample and Buffer well.
To use a Dropper:
5. Hold the dropper vertically and fill the capillary part of the dropper (not to exceed the capillary part) with Serum, Plasma or Whole blood specimen (10 μL), then carefully dispense the specimen into the Sample Well (S) of the test cassette. then add 2 drops of buffer into the Buffer Well (B) and start the timer. Avoid air bubbles in the Sample and Buffer well.
6. Wait for the colored line(s) to appear and read the results at 15 minutes. Do not interpret the result after 20 minutes. If positive signal appears after 20 minutes, it should not be reported as positive.
Leave A Message

Please provide us with the information below, and we'll contact you as soon as possible.

Related Products
The Dengue NS1 Antigen Qualitative Rapid Test
The Dengue NS1 Antigen Rapid Test
The Dengue NS1 Antigen Rapid Test is a lateral flow immunoassay for the qualitative detection of Dengue virus NS1 antigen in human serum, plasma or whole blood. It is intended to be used by professionals as a screening test and provides a preliminary test result to aid in the diagnosis of infection with the dengue virus. For professional in vitro diagnostic use only.
Dengue IgG/IgM Rapid Test
Dengue IgG/IgM Rapid Test
The Dengue IgG/IgM Rapid Test is a rapid membrane based chromatographic immunoassay for qualitative and differential detection of IgG and IgM antibodies to all four serotypes (DEN-1, DEN-2, DEN- 3 and DEN-4) of Dengue virus in human serum, plasma or whole blood. It is intended to be used by professionals as a screening test and provides a preliminary test result to aid in the diagnosis of primary and secondary Dengue infection. For professional in vitro diagnostic use only.
Biotime BIOT-YG-I FIA Immunoassay Analyzer (Fluorescence Immunoassay Analyzer)
BIOT-YG-I FIA Immunoassay Analyzer (Fluorescence Immunoassay Analyzer)
BIOT-YG-I is a fluorescence immunoassay system with single channel that measures the quantitative concentration of a targeted analyte in human blood and urine.
biotime tPSA Rapid Quantitative Test
tPSA Rapid Quantitative Test
Prostate-specific antigen, or PSA, is a protein produced by normal, as well as malignant, cells of the prostate gland. The PSA test measures the level of PSA in a man's blood.
Chemiluminescence Immunoassay
CLi-1600 CLIA Analyzer
CLi-1600 semi-automated device which quantifies biomarkers for thyroid disease, inflammation, cardiac diseases, fertility, diabetes, bone metabolism, anemia, and health check by analyzing human serum, plasma and whole blood.
biotime NGAL Rapid Quantitative Test
NGAL Rapid Quantitative Test
NGAL (neutrophil gelatinase-associated lipocalin, lipocalin-2, sidero- calin) is a novel biomarker for diagnosing acute kidney injury (AKI). Under normal conditions NGAL levels are low in urine and plasma Still, they rise sharply from basal levels in response to kidney injury to reach diagnostic levels within a very short time - as much as 24 hours or more before any significant rise in serum creatinine.
Biotime HLC-100 Fully Automated HbA1c Analyzer
HLC-100 Fully Automated HbA1c Analyzer
Biotime’s HLC-100 Fully Automated HbA1c Analyzer provides a prompt, reliable solution for diabetes diagnosis. It utilizes the high performance liquid chromatography (HPLC) analytical technique, a gold standard that helps detect glycosylated hemoglobin (HbA1c) with superior precision. Its capability to measure HbA1c, HbF, and other hemoglobin fragments enables clinicians to make quick, accurate diagnoses, thus facilitating timely treatment for the patient.
Covid-19 Test
COVID-19 Ag & Flu A/B Combo Self Test
COVID-19 Ag & Flu A/B Combo Self Test is a colloidal gold immunochromatography intended for the in vitro rapid, simultaneous qualitative detection and differentiation of N protein from SARS-CoV-2, influenza A and influenza B directly from nasal swab specimens obtained from individuals, who are suspected of COVID-19, influenza A or influenza B infection. Results are for the simultaneous identification of N protein of SARS-CoV-2, influenza A and influenza B.
Leave A Message

Leave A Message

    Please provide us with the information below, and we'll contact you as soon as possible.

Home

products

about