Ferritin Quantitative Test

Dengue Ag&Ab Combo Rapid Test

The Dengue Ag&Ab Combo Rapid Test is a rapid membrane based chromatographic immunoassay for for the qualitative detection of NS1 antigen and IgM/IgG antibodies to all four serotypes (DEN-1, DEN-2, DEN-3 and DEN-4) of Dengue virus in human serum, plasma or whole blood. It is intended to be used by professionals as a screening test and provides a preliminary test result to aid in the diagnosis of primary and secondary Dengue infection.


For professional in vitro diagnostic use only.




Product Detail

Features


  • Highly Sensitive & Specific
  • Flexible Samply Type
  • Fast in 15 minutes
  • Simple Operation

Included Materials


  • Test Cassette 
  • Sample Buffer
  • Droppers
  • Instruction for Use


Test Procedure 


The test should be operated at room temperature 59-86°F(15-30℃).
1. Allow the test cassette, specimen and buffer to reach room temperature (15-30°C) before testing.
2. Remove the test cassette from the foil pouch and use it as soon as possible.

3. Place the test cassette on a flat and clean surface. Transfer the specimen by a pipette or a dropper:

To use a Pipette:

4. Transfer 10 μL of Serum, Plasma, or Whole blood specimen into the Sample Well (S) of the test cassette, then add 2 drops of buffer into the Buffer Well (B) and start the timer. Avoid air bubbles in the Sample and Buffer well.
To use a Dropper:
5. Hold the dropper vertically and fill the capillary part of the dropper (not to exceed the capillary part) with Serum, Plasma or Whole blood specimen (10 μL), then carefully dispense the specimen into the Sample Well (S) of the test cassette. then add 2 drops of buffer into the Buffer Well (B) and start the timer. Avoid air bubbles in the Sample and Buffer well.
6. Wait for the colored line(s) to appear and read the results at 15 minutes. Do not interpret the result after 20 minutes. If positive signal appears after 20 minutes, it should not be reported as positive.
Leave A Message

Please provide us with the information below, and we'll contact you as soon as possible.

Related Products
Dengue NS1 Antigen Qualitative Rapid Test
Dengue NS1 Antigen Rapid Test
The Dengue NS1 Antigen Rapid Test is a lateral flow immunoassay for the qualitative detection of Dengue virus NS1 antigen in human serum, plasma or whole blood. It is intended to be used by professionals as a screening test and provides a preliminary test result to aid in the diagnosis of infection with the dengue virus. For professional in vitro diagnostic use only.
Dengue IgG/IgM Rapid Test
Dengue IgG/IgM Rapid Test
The Dengue IgG/IgM Rapid Test is a rapid membrane based chromatographic immunoassay for qualitative and differential detection of IgG and IgM antibodies to all four serotypes (DEN-1, DEN-2, DEN- 3 and DEN-4) of Dengue virus in human serum, plasma or whole blood. It is intended to be used by professionals as a screening test and provides a preliminary test result to aid in the diagnosis of primary and secondary Dengue infection. For professional in vitro diagnostic use only.
Biotime HLC-100 Fully Automated HbA1c Analyzer
HLC-100 Fully Automated HbA1c Analyzer
Biotime’s HLC-100 Fully Automated HbA1c Analyzer provides a prompt, reliable solution for diabetes diagnosis. It utilizes the high performance liquid chromatography (HPLC) analytical technique, a gold standard that helps detect glycosylated hemoglobin (HbA1c) with superior precision. Its capability to measure HbA1c, HbF, and other hemoglobin fragments enables clinicians to make quick, accurate diagnoses, thus facilitating timely treatment for the patient.
Incubation Chamber
ICE-100E Incubation Chamber
The incubation chamber is an auxiliary device for Biotime’s fluorescence immunoassay analyzer. The reaction temperature and time is critical for test results. The incubation chamber provides an optimized environment as well as automatic timers for test reactions to improve the reliability of test results.
IL-6 Rapid Quantitative Test (Chemiluminescence Immunoassay)
IL-6 Rapid Quantitative Test (Chemiluminescence Immunoassay)
IL-6 Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Interleukin-6 (IL-6) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of inflammation diseases.
TESTO Rapid Quantitative Test (Chemiluminescence Immunoassay)
TESTO Rapid Quantitative Test (Chemiluminescence Immunoassay)
TESTO Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Testosterone (TESTO) concentration in human serum and plasma that contains heparin /EDTA and other anticoagulants samples, mainly used for auxiliary diagnosis of reproductive hormones diseases.
Biotime PRL  Rapid Quantitative Test
PRL Rapid Quantitative Test
Prolactin is the hormone that tells the body to make breast milk when a person is pregnant or breast-feeding. Production of prolactin takes place in the pituitary gland. For those who are not pregnant or breast-feeding, there are only low levels of prolactin in the body.
biotime PGI Rapid Quantitative Test
PGI Rapid Quantitative Test
Human Pepsinogens are aspartic proteases produced in the gastric mucosa and secreted into the gastric lumen that play a major role in the digestion of proteins after activation of acidic pH. It is synthesized as isoymogens and is classified into two groups (Pepsinogen I and Pepsinogen II).