Ferritin Quantitative Test

TSH Rapid Quantitative Test(Chemiluminescence Immunoassay)

TSH Rapid Quantitative Test(Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the thyroid stimulating hormone concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of thyroid diseases.

Product Detail

Application

The main physiological function of thyroid-stimulating hormone (TSH) is to bind to specific receptors on the surface of thyroid follicular cells, promoting the synthesis and secretion of thyroid hormones. The secretion of TSH is regulated not only by the stimulatory input from the hypothalamus, but also by the negative feedback of thyroid hormones themselves.

 

The measurement of TSH levels in the blood can be a useful tool in the auxiliary diagnosis of thyroid diseases, as well as for monitoring the therapeutic effects in related patients. Determining TSH levels provides valuable information about the functional state of the thyroid gland, and can help clinicians assess and manage various thyroid disorders.

 

Product Specification

Sample Volume

WB: 40μL; Serum/Plasma: 20μL

Test Time

15 mins

Measuring Range

0.05-100 mIU/L

Pack

20T、40T、100T

Storage

2~30℃

 

Features

Smart - Photosensitive and Luminescent Microspheres

Rapid - Whole Blood Sample Type Supported & No Centrifuge Needed

Convenient - Room Temperature Storage & Minimal sample consumption

 

Clinical significance

Thyroid Function Assessment

Hypothyroidism Diagnosis and Monitoring

Hyperthyroidism Diagnosis and Monitoring

Thyroid Medication Adjustment

Fertility Assessment

Leave A Message

Please provide us with the information below, and we'll contact you as soon as possible.

Related Products
FT4 Rapid Quantitative Test (Chemiluminescence Immunoassay)
FT4 Rapid Quantitative Test (Chemiluminescence Immunoassay)
FT4 Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Free thyroxine 4 (FT4) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of thyroid diseases.
TT4 Rapid Quantitative Test (Chemiluminescence Immunoassay)
TT4 Rapid Quantitative Test (Chemiluminescence Immunoassay)
TT4 Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the total thyroxine 4 (TT4) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of thyroid diseases.
FT3 Rapid Quantitative Test (Chemiluminescence Immunoassay)
FT3 Rapid Quantitative Test (Chemiluminescence Immunoassay)
FT3 Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Free triiodothyronine 3 (FT3) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of thyroid diseases.
TT3 Rapid Quantitative Test (Chemiluminescence Immunoassay)
TT3 Rapid Quantitative Test (Chemiluminescence Immunoassay)
TT3 Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Total Triiodothyronine (TT3) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of thyroid diseases.
CMV IgG/IgM Rapid Test (Fluorescence Immunoassay)
CMV IgG/IgM Rapid Test (Fluorescence Immunoassay)
TheCMV IgG/IgM Rapid Test is an in vitro immunoassay for the in vitro qualitative determination of IgG and IgM class antibodies toCMV in human serum. IgG results with this assay are used to indicate past or recent infection with CMV. IgM results obtained with this assay are used as an aid in the diagnosis of acute or recent CMV infections. CMV IgM test shall not be used for prenatal screening of asymptomatic people, and the test results of this reagent shall not be used alone as the basis for termination of pregnancy. -Fluorescent immunoassay -Cytomegalovirus (CMV) infection -For in vitro diagnostic use only. For professional use only.
CK-MB Rapid Quantitative Test (Chemiluminescence Immunoassay)
CK-MB Rapid Quantitative Test (Chemiluminescence Immunoassay)
CK-MB Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Creatine kinase-MB (CK-MB) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of cardiac diseases.
Dengue IgG/IgM Antibody Rapid Qualitative Test (Fluorescence Immunoassay)
Dengue IgG/IgM Antibody Rapid Qualitative Test (Fluorescence Immunoassay)
The Biotime DengueIgG/IgM Antibody Rapid Testis intended to qualitatively detect the dengue IgG/IgM antibody in human serum, plasma or whole blood samples on Biotime FIA Analyzer byfluorescent immunoassay. The test is used asthe early aid diagnosis and screening of dengue virus infection. For in vitro diagnostic use only. For professional use only.
FIA Analyzer
FLI-100 FIA Analyzer
The ALL NEW FLI-100 Analyser represents an elevated standard at Biotime, in pursuing simplicity, quality assurance, and data security for healthcare organizations. Designed for quantitative in vitro assay determinations, the Biotime FLI-100 analyser was purposefully built to support immunoassay analysis for a broad range of applications – from biomarker work to infectious disease testing. The analyser’s immunofluorescence technology yields high sensitivity, reliable, and reproducible results for convenient point-of-care diagnostic testing on one device with a small footprint.
Leave A Message

Leave A Message

    Please provide us with the information below, and we'll contact you as soon as possible.

Home

products

about

contact