Ferritin Quantitative Test

TT3 Rapid Quantitative Test (Chemiluminescence Immunoassay)

TT3 Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Total Triiodothyronine (TT3) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of thyroid diseases.

Product Detail

Application

Triiodothyronine (T3) and thyroxine (T4) are the two primary thyroid hormones secreted by the thyroid gland. Their production and release are regulated by thyroid-stimulating hormone (TSH), which is secreted by the anterior pituitary gland. As such, serum T3 concentrations primarily reflect the functional state of the peripheral tissues, rather than the secretory capacity of the thyroid gland itself. A decrease in the conversion of T4 to T3 can result in a reduction of circulating T3 levels.

 

Thyroid dysfunction can lead to either an overproduction (hyperthyroidism) or underproduction (hypothyroidism) of T3 and T4. Additionally, thyroid function can be affected if the pituitary gland or hypothalamus is dysfunctional, due to the direct influence of TSH.

 

The measurement of blood T3 levels can be used as an aid in the diagnosis of various thyroid disorders, as well as for monitoring the effectiveness of treatment in related patients. By assessing T3 concentrations, clinicians can gain valuable insights into the underlying thyroid hormone dynamics, which is crucial for the effective management of thyroid diseases.

 

Product Specification

Sample Volume

WB: 40μL; Serum/Plasma: 20μL

Test Time

15 mins

Measuring Range

0.195-6.51 ng/mL

Pack

20T40T100T

Storage

2~30

 

Features

Smart - Photosensitive and Luminescent Microspheres

Rapid - Whole Blood Sample Type Supported & No Centrifuge Needed

Convenient - Room Temperature Storage & Minimal sample consumption

 

Clinical significance

1. Thyroid Function Assessment

2. Diagnosis and Monitoring of Hyperthyroidism

3. Assessment of Thyroid Medication Dosage

4. Evaluation of Thyroid Disorders in Pregnancy

5. Assessment of Thyroid Nodule Function

Leave A Message

Please provide us with the information below, and we'll contact you as soon as possible.

Related Products
TSH Rapid Quantitative Test(Chemiluminescence Immunoassay)
TSH Rapid Quantitative Test(Chemiluminescence Immunoassay)
TSH Rapid Quantitative Test(Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the thyroid stimulating hormone concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of thyroid diseases.
FT4 Rapid Quantitative Test (Chemiluminescence Immunoassay)
FT4 Rapid Quantitative Test (Chemiluminescence Immunoassay)
FT4 Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Free thyroxine 4 (FT4) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of thyroid diseases.
TT4 Rapid Quantitative Test (Chemiluminescence Immunoassay)
TT4 Rapid Quantitative Test (Chemiluminescence Immunoassay)
TT4 Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the total thyroxine 4 (TT4) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of thyroid diseases.
FT3 Rapid Quantitative Test (Chemiluminescence Immunoassay)
FT3 Rapid Quantitative Test (Chemiluminescence Immunoassay)
FT3 Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Free triiodothyronine 3 (FT3) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of thyroid diseases.
FIA Analyzer
FLI-100 FIA Analyzer
The ALL NEW FLI-100 Analyser represents an elevated standard at Biotime, in pursuing simplicity, quality assurance, and data security for healthcare organizations. Designed for quantitative in vitro assay determinations, the Biotime FLI-100 analyser was purposefully built to support immunoassay analysis for a broad range of applications – from biomarker work to infectious disease testing. The analyser’s immunofluorescence technology yields high sensitivity, reliable, and reproducible results for convenient point-of-care diagnostic testing on one device with a small footprint.
biotime HCV Rapid Quantitative Test
HCV Rapid Quantitative Test
Hepatitis C is a liver disease caused by the hepatitis C virus (HCV): the virus can cause both acute and chronic hepatitis, ranging in severity from a mild illness lasting a few weeks to a serious, lifelong illness. Hepatitis C is a major cause of liver cancer.
Biotime Myo Rapid Quantitative Test
Myo Rapid Quantitative Test
Myo is the earliest marker after AMI, and it is a sensitive and accurate indicator to judge whether there is reperfusion in thrombolytic therapy. Biotime Myo test kit is mainly used to detect Myo quantity in human serum and plasma samples.
 TT3 Rapid Quantitative Test
TT3 Rapid Quantitative Test
TT3 is the main hormone that thyroid hormone does to various target organs. The serum TT3 concentration reflects the thyroid gland’s ability to function better than the thyroid gland. TT3 is an important indicator of early hyperthyroidism and the monitoring of recurrent hyperthyroidism and pseudo thyrotoxicosis.
Leave A Message

Leave A Message

    Please provide us with the information below, and we'll contact you as soon as possible.

Home

products

about

contact