Ferritin Quantitative Test

CLi-1600 CLIA Analyzer

CLi-1600 semi-automated device which quantifies biomarkers for thyroid disease, inflammation, cardiac diseases, fertility, diabetes, bone metabolism, anemia, and health check by analyzing human serum, plasma and whole blood.

Product Detail



Advantages

√ Rapid: fastest result in 5mins

√ Flixible: Whole blood option & Zero cost of Consumables

√ Vast Applications: Big&Small Medical facilities

√ Room temperature storage: 2-30°C

√ Simplest test procedure: results in 3 steps 


Technical Data

Model
CLi-1600 Analyzer
Principle
Chemiluminescence Immunoassay
Specimen Whole Blood/ Serum/ Plasma/ Urine
Sample Position
16 channels
Wavelength
680 nm
Printer
Built-in thermal printer
Reader
Photon multiplier tube (PMT)
Incubation temperature
25℃±1℃
Size
312 × 382 × 345mm
Weight
15 kg


Application Departments

ICU; Clinical Laboratory; Cardiology Dept; Emergency Dept.; Endocrinology Dept.; Nephrology Dept.; Oncology Dept.; Pediatrics Dept.; Urology Dept.; Respiratory Dept.; Gynecology Dept.; Gastroenterology Dept.


Test Parameters

Cardiac Markers
CTnI, MYO, CK-MB, NT-proBNP, D-Dimer, CTnI/MYO/CK-MB, CTnI/MYO/CK-MB/NT-proBNP/D-Dimer, HCY, h-FABP, BNP, ST2, LP-PLA2
Hormones Markers
β-HCG, PROG, E2, TES, FSH, LH, PRL, FSH/LH/PRL, AMH
Inflammation Markers
PCT, SAA, hsCRP+CRP, CRP/SAA, Total IgE, IL-6
Thyroid Markers
TSH, TT3, TT4, fT3, fT4
Diabetes and Renal Injury
HbA1c, MAU, Cys-C, NGAL
Tumor Markers
 CEA, AFP, CEA/AFP, tPSA, fPSA, PGI, PGII, PGI/PGII
Health Check
25(OH)-D, Ferritin
Infectious Disease
HBsAg, HCV

Leave A Message

Please provide us with the information below, and we'll contact you as soon as possible.

Related Products
HbA1c Analyzer
HLC-100 Fully Automated HbA1c Analyzer
Biotime’s HLC-100 Fully Automated HbA1c Analyzer provides a prompt, reliable solution for diabetes diagnosis. It utilizes the high performance liquid chromatography (HPLC) analytical technique, a gold standard that helps detect glycosylated hemoglobin (HbA1c) with superior precision. Its capability to measure HbA1c, HbF, and other hemoglobin fragments enables clinicians to make quick, accurate diagnoses, thus facilitating timely treatment for the patient.
biotime PGI Rapid Quantitative Test
PGI Rapid Quantitative Test
Human Pepsinogens are aspartic proteases produced in the gastric mucosa and secreted into the gastric lumen that play a major role in the digestion of proteins after activation of acidic pH. It is synthesized as isoymogens and is classified into two groups (Pepsinogen I and Pepsinogen II).
Biotime fT4 Rapid Quantitative Test
FT4 Rapid Quantitative Test (Fluorescence Immunoassay)
The Biotime FT4Rapid Quantitative Test is intended to quantify the concentration of FT4 in human serum on the Biotime FIA Analyzer (Semi-automatic / Automatic) by fluorescent immunoassay. The test is used as an aid in the detection of hyperthyroidism. -Fluorescence immunoassay -hyperthyroidism For in vitro diagnostic use only. For professional use only.
Biotime ST2 Rapid Quantitative Test
ST2 Rapid Quantitative Test
ST2 is a member of the interleukin-1 receptor family biomarker and circulating soluble ST2 concentrations are believed to reflect cardiovascular stress and fibrosis. The studies have demonstrated soluble ST2 to be a strong predictor of cardiovascular outcomes in both chronic and acute heart failure. It is a new biomarker that meets all required criteria for a useful biomarker.
CRP Rapid Quantitative Test (Chemiluminescence Immunoassay)
CRP Rapid Quantitative Test (Chemiluminescence Immunoassay)
CRP Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the C-reactive proteins (CRP) concentration in human serum, plasma and vein whole blood specimens.
TSH Rapid Quantitative Test(Chemiluminescence Immunoassay)
TSH Rapid Quantitative Test(Chemiluminescence Immunoassay)
TSH Rapid Quantitative Test(Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the thyroid stimulating hormone concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of thyroid diseases.
h-FABP Rapid Quantitative Test (Chemiluminescence Immunoassay)
h-FABP Rapid Quantitative Test (Chemiluminescence Immunoassay)
h-FABP Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the heart-type fatty acid binding protein (h-FABP) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of cardiac diseases.
FSH Rapid Quantitative Test (Chemiluminescence Immunoassay)
FSH Rapid Quantitative Test (Chemiluminescence Immunoassay)
FSH Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Follicle-stimulating hormone (FSH) concentration in human serum and plasma that contains heparin /EDTA and other anticoagulants samples, mainly used for auxiliary diagnosis of reproductive hormones diseases.
Leave A Message

Leave A Message

    Please provide us with the information below, and we'll contact you as soon as possible.

Home

products

about

contact