HLC-100 Fully Automated HbA1c Analyzer

Biotime’s HLC-100 Fully Automated HbA1c Analyzer provides a prompt, reliable solution for diabetes diagnosis. It utilizes the high performance liquid chromatography (HPLC) analytical technique, a gold standard that helps detect glycosylated hemoglobin (HbA1c) with superior precision. Its capability to measure HbA1c, HbF, and other hemoglobin fragments enables clinicians to make quick, accurate diagnoses, thus facilitating timely treatment for the patient.

Product Detail


Advantages:

12 sample positions 

HbA1c analysis in 2 minutes 

The gold standard for the detection HbA1c


Technical Data

Principle
High Performance Liquid Chromatography (HPLC)
Specimen
Whole blood
Channel
10 sample channels +2 Emergency channels
Linear
3-18%
Wavelength
415 nm
Processing Speed
2min/Test
CV
≤2%
Sample Volume
4μL (Minimum 1ml in the sample tube)
Carryover rate
≤3%
Memory
10000
Reagent configuration
Eluent A/ eluent B/ diluent C
Screen
7" color touch screen, wins10 operating system
Printer
Build-in thermal printer or external device
Dimensions
D328mm*W405mm*H422mm
Power Supply
24V
Weight
24KG


Leave A Message

Please provide us with the information below, and we'll contact you as soon as possible.

Related Products
Biotime Lp PLA2 Rapid Quantitative Test
Lp-PLA2 Rapid Quantitative Test
Lipoprotein-associated phospholipase A2 (Lp-PLA2) is an enzyme that plays a role in the inflammation of blood vessels and is thought to help promote atherosclerosis. Biotime rapid quantitative test kit measures the amount or activity of Lp-PLA2 in the human blood.
TSH/TT3/TT4 Rapid Quantitative Test (Fluorescence Immunoassay)
TSH/TT3/TT4 Rapid Quantitative Test (Fluorescence Immunoassay)
The Biotime TSH/TT3/TT4Rapid Quantitative Testis intended to quantitatively detect theconcentration of thyroid stimulating hormone (TSH),total triiodothyronine (TT3) and total thyroxine (TT4) in human serum and plasma samples on Biotime FIA Analyzer byfluorescent immunoassay. The test is used as an aiddiagnosis of thyroiddisease. For in vitro diagnostic use only. For professional use only.
Incubation Chamber
ICE-100E Incubation Chamber
The incubation chamber is an auxiliary device for Biotime’s fluorescence immunoassay analyzer. The reaction temperature and time is critical for test results. The incubation chamber provides an optimized environment as well as automatic timers for test reactions to improve the reliability of test results.
Biotime Myo Rapid Quantitative Test
Myo Rapid Quantitative Test
Myo is the earliest marker after AMI, and it is a sensitive and accurate indicator to judge whether there is reperfusion in thrombolytic therapy. Biotime Myo test kit is mainly used to detect Myo quantity in human serum and plasma samples.
AMH Rapid Quantitative Test (Chemiluminescence Immunoassay)
AMH Rapid Quantitative Test (Chemiluminescence Immunoassay)
AMH Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Anti-Mullerian hormone (AMH) concentration in human serum and plasma that contains heparin /EDTA and other anticoagulants samples, mainly used for auxiliary diagnosis of reproductive hormones diseases.
Dengue NS1 Antigen Qualitative Rapid Test
Dengue NS1 Antigen Rapid Test
The Dengue NS1 Antigen Rapid Test is a lateral flow immunoassay for the qualitative detection of Dengue virus NS1 antigen in human serum, plasma or whole blood. It is intended to be used by professionals as a screening test and provides a preliminary test result to aid in the diagnosis of infection with the dengue virus. For professional in vitro diagnostic use only.
biotime HCV Rapid Quantitative Test
HCV Rapid Quantitative Test
Hepatitis C is a liver disease caused by the hepatitis C virus (HCV): the virus can cause both acute and chronic hepatitis, ranging in severity from a mild illness lasting a few weeks to a serious, lifelong illness. Hepatitis C is a major cause of liver cancer.
Cys C Rapid Quantitative Test
Cys-C Rapid Quantitative Test
Serum Cystatin C(Cys-C) has been proposed as a marker of glomerular filtration rate(GFR). Serum creatinine (creatinine) is widely used to estimate the glomerular filtration rate, but its tubular secretion, dependence on muscle mass, alteration in some inflammatory diseases, and analytical interferences can limit its utility. Thus, Cys-C has been proposed as a novel biomarker of kidney function.
Leave A Message

Leave A Message

    Please provide us with the information below, and we'll contact you as soon as possible.

Home

products

about

contact