Ferritin Quantitative Test

IL-6 Rapid Quantitative Test (Chemiluminescence Immunoassay)

IL-6 Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Interleukin-6 (IL-6) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of inflammation diseases.

Product Detail

Application

Interleukin-6 (IL-6) is a pleiotropic cytokine involved in the physiology of virtually every organ system. Recent studies have demonstrated that IL-6 plays a crucial role in regulating the balance between IL-17-producing T helper 17 (Th17) cells and regulatory T (Treg) cells.

 

These two T-cell subsets play prominent and opposing roles in immune functions. Th17 cells are key players in the pathogenesis of autoimmune diseases and provide protection against certain bacterial infections, while Treg cells function to restrain excessive effector T-cell responses.

 

IL-6 induces the development of Th17 cells from naïve T cells, in conjunction with transforming growth factor-beta (TGF-β). In contrast, IL-6 inhibits the TGF-β-induced differentiation of Treg cells. This modulation of the Th17/Treg balance by IL-6 is an important mechanism underlying its involvement in both autoimmunity and host defense.

 

Product Specification

Sample Volume

WB: 40μL; Serum/Plasma: 20μL

Test Time

10 mins

Measuring Range

5-5000 pg/mL

Pack

20T40T100T

Storage

2~30

 

Features

Smart - Photosensitive and Luminescent Microspheres

Rapid - Whole Blood Sample Type Supported & No Centrifuge Needed

Convenient - Room Temperature Storage & Minimal sample consumption

 

Clinical significance

Rheumatoid Arthritis and Autoimmune Diseases

Cytokine Release Syndrome (CRS) Assessment

Sepsis and Inflammatory Response

Assessment of Inflammatory Bowel Disease (IBD)

Cardiovascular Risk Assessment

Leave A Message

Please provide us with the information below, and we'll contact you as soon as possible.

Related Products
CRP Rapid Quantitative Test (Chemiluminescence Immunoassay)
CRP Rapid Quantitative Test (Chemiluminescence Immunoassay)
CRP Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the C-reactive proteins (CRP) concentration in human serum, plasma and vein whole blood specimens.
PCT Rapid Quantitative Test (Chemiluminescence Immunoassay)
PCT Rapid Quantitative Test (Chemiluminescence Immunoassay)
PCT Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Procalcitonin concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of inflammation diseases.
SAA Rapid Quantitative Test (Chemiluminescence Immunoassay)
SAA Rapid Quantitative Test (Chemiluminescence Immunoassay)
SAA Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Serum amyloid A (SAA) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of inflammation diseases.
HBP Rapid Quantitative Test (Chemiluminescence Immunoassay)
HBP Rapid Quantitative Test (Chemiluminescence Immunoassay)
HBP Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Heparin binding protein (HBP) concentration in human plasma that contains Sodium Citrate samples, mainly used for auxiliary diagnosis of inflammation diseases.
Biotime BNP Rapid Quantitative Test
BNP Rapid Quantitative Test
During heart failure, the heart makes two proteins, called B-type natriuretic peptide (BNP) and N-terminal-pro-BNP (NT-proBNP). Levels of both in the blood go up when heart failure gets worse and go down when it gets better.
NT-proBNP Rapid Quantitative Test (Chemiluminescence Immunoassay)
NT-proBNP Rapid Quantitative Test (Chemiluminescence Immunoassay)
NT-proBNP Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the N-terminal pro-B-type natriuretic peptide(NT-proBNP) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of cardiac diseases.
Dengue NS1 Antigen Qualitative Rapid Test
Dengue NS1 Antigen Rapid Test
The Dengue NS1 Antigen Rapid Test is a lateral flow immunoassay for the qualitative detection of Dengue virus NS1 antigen in human serum, plasma or whole blood. It is intended to be used by professionals as a screening test and provides a preliminary test result to aid in the diagnosis of infection with the dengue virus. For professional in vitro diagnostic use only.
S100-β Rapid Quantitative Test (Fluorescence Immunoassay)
S100-β Rapid Quantitative Test (Fluorescence Immunoassay)
The Biotime S100-β Rapid Quantitative Test is intended to quantify the concentration of S100-β in human serum, plasma, and whole blood on the Biotime FIA Analyzer by fluorescent immunoassay. The test is used as an aid in the detection of neurological injury.
Leave A Message

Leave A Message

    Please provide us with the information below, and we'll contact you as soon as possible.

Home

products

about

contact